Series Resonant Converter (SRC)
Half-bridge resonant DC-DC converter (24V in, ~12V out). LC resonant tank (Lr=100µH, Cs=47nF, fr=73.4kHz) with fast-recovery rectifier.
Key Components
- 2× MOSFET
- LC Resonant Tank
- Diode Bridge
- Pulse Gen
Simulation Analysis
This template comes pre-configured with a transient profile. Just click the "Run" button inside the simulator to instantly view the waveform output.
Circuit Theory & Operating Principle
A half-bridge Series Resonant Converter (SRC) alternates two power MOSFETs at high frequency (near fr = 1/(2π√(Lr·Cs))) to drive a bipolar square wave into a series LC resonant tank coupled into a full-wave bridge rectifier and filter capacitor. Because current flows sinusoidally around resonance rather than in hard rectangular pulses, transistors achieve Zero-Current Switching (ZCS) or Zero-Voltage Switching (ZVS), slashing switching losses.
Operating slightly above series resonant frequency fr places the LC tank in inductive lag, guaranteeing ZVS turn-on of the MOSFETs without body-diode reverse-recovery spikes. Vary switching frequency upward above resonance to decrease voltage gain under lighter load conditions, or lock near 1:1 tank ratio for maximum efficiency isolated DC-DC buses.
Key Design Equations
- fr = 1 / (2 × π × √(Lr × Cs))
- Z0 (characteristic impedance) = √(Lr / Cs)
- Q = Z0 / R_ac, R_ac = (8 / π²) × Rload
Typical Component Values
- 24 V → 12 V half-bridge tank: Lr = 100 µH, Cs = 47 nF (fr ≈ 73.4 kHz)
- Half-bridge switches: 2 × IRF540N / low-Qg power NMOS
- Output rectifier & bulk cap: Fast recovery bridge + 47 µF – 220 µF
Expected SPICE Simulation Result
Resonant tank current shapes into clean smooth sinusoids at switching transitions while the output capacitor climbs steadily from 0 V and regulates smoothly near Vdc/2 (~12 V from a 24 V bus).